GMU:DIY-Microscopy/Cathleen: Difference between revisions

From Medien Wiki
mNo edit summary
m (Undo revision 46176 by Max (talk))
Line 3: Line 3:
[[File:MicroscopeCamera.jpg|390px|thumb|wedge approach Cathleen]]
[[File:MicroscopeCamera.jpg|390px|thumb|wedge approach Cathleen]]
Approach with 2 wedges. The aim was to find a simple mechanism that allows for high precision. If you tighten the screw the lower wedge moves left and pushes up the upper wedge with the camera on top of it. If you loosen the screw the camera moves down.   
Approach with 2 wedges. The aim was to find a simple mechanism that allows for high precision. If you tighten the screw the lower wedge moves left and pushes up the upper wedge with the camera on top of it. If you loosen the screw the camera moves down.   
Because of its simplicity it would be less susceptible to errors.
Because of its simplicity it would be less susceptible to errors.<br clear="both" />
<br clear="both" />


== 3D Model ==
== 3D Model ==
 
[[File:Modell3DStellung1.png|390px|thumb|position 1]]
[[File:Modell3DStellung1.png]]
[[File:Modell3DStellung2.png|390px|thumb|position 2]]
 
[[File:Animation.gif]]
[[File:Modell3DStellung2.png]]

Revision as of 20:28, 4 November 2012

Miroscopy stage construction

wedge approach Cathleen

Approach with 2 wedges. The aim was to find a simple mechanism that allows for high precision. If you tighten the screw the lower wedge moves left and pushes up the upper wedge with the camera on top of it. If you loosen the screw the camera moves down. Because of its simplicity it would be less susceptible to errors.

3D Model

position 1
position 2

Animation.gif